Pelco Home Security System C490M D 1 96 User Manual

®
HS1000 High-Security  
Camera Enclosure  
Installation/Operation Manual  
C490M-D (1/96)  
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827  
 
LIST OF ILLUSTRATIONS  
Figure  
Page  
1
2
3
4
5
6
7
HS1000 Dimension Drawing .......................................................................................................... 3  
HB6000, HB6000/220, and HB6024 Assembly.............................................................................. 5  
HS1000 Series Tamper Switch Installation .................................................................................... 6  
HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC) ........................................................... 7  
HB6000 Heater/Blower Kit Wiring Diagram (120 VAC) .................................................................. 7  
HB6024 Heater/Blower Kit Wiring Diagram (24 VAC) .................................................................... 8  
HS1000 Enclosure Exploded Assembly Diagram .......................................................................... 9  
REVISION HISTORY  
Manual #  
C490M  
Date  
5/90  
Comments  
Original version.  
C490M-A  
12/94  
Revised manual to include new exploded assembly  
diagram, updated parts list, and modified wall mounting  
instructions as per ECO# 93-245.  
C490M-B  
C490M-C  
C490M-D  
9/95  
11/95  
1/96  
Revised to include wiring instructions for tamper switch  
and metric equivalents for specifications.  
Revised to include updated tamper switch/bracket part  
numbers and exploded view diagram.  
Revised to include tamper switch installation, specifica-  
tion description and new part numbers per ECO 95-397.  
Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
© Copyright 1996, Pelco. All rights reserved.  
Pelco Manual C490M-D (1/96)  
iii  
 
(This page intentionally left blank.)  
iv  
Pelco Manual C490M-D (1/96)  
 
INSTALLATION/OPERATION  
HS1000 HIGH-SECURITY  
CAMERA ENCLOSURE  
1.0 WARNINGS  
3. OnlyusereplacementpartsrecommendedbyPelco.  
Priortoinstallationanduseofthisproduct,thefollowing  
WARNINGS should be observed.  
4. The installation method and materials should be  
capable of supporting 4 times the weight of the  
enclosure, camera and lens combination.  
1. Installation and servicing should only be done by  
Qualified Service Personnel and conform to all  
Local codes.  
5. The camera and lens combination shall not exceed  
2. Unless the unit is specifically marked as a NEMA  
Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is  
designed for Indoor use only and it must not be  
installed where exposed to rain and moisture.  
20 lbs (9.06 kg).  
The product may bear the following  
marks:  
This symbol indicates that dangerous voltage  
constituting a risk of electric shock is present  
within this unit.  
This symbol indicates that there are important  
operating and maintenance instructions in the  
literature accompanying this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
CAUTION:  
TOREDUCETHERISKOFELECTRICAL  
SHOCK, DO NOT REMOVE COVER. NO  
USER-SERVICEABLE PARTS INSIDE.  
REFER SERVICING TO QUALIFIED  
SERVICE PERSONNEL.  
Please thoroughly familiarize yourself with the information in this manual  
prior to installation and operation.  
Pelco Manual C490M-D (1/96)  
1
 
2.0 SCOPE  
4.0 INSTALLATION  
The information within this manual covers the installa-  
tion of the HS1000 High Security Camera Enclosure.  
Before installing the HS1000 to a wall/ceiling, make  
certain that the mounting surfaces are able to support  
the full weight of the enclosure, plus the camera/lens  
and any other options, (i.e., speakers, infrared illumi-  
nators, heater/blower kits and/or hoods).  
Installation should be in accordance with all applicable  
local and national electric codes, utilizing approved ma-  
terials only.  
The tilt table and the tilt table mounting bracket may  
be removed to provide adequate clearance for mount-  
ing the enclosure.  
3.0 DESCRIPTION  
The HS1000 is a large, high-security camera enclosure  
designed for indoor “corner mount” installation for such  
applications as parking garages, prisons, detention cells,  
etc., requiring maximum protection from vandalism.  
The front cover and bottom plate can be removed from  
the mounting frame to simplify installation.  
NOTE: The eight (8) to twelve (12) fasteners  
required to secure the HS1000 to a wall/ceiling  
(minimum 3/8-inch diameter fasteners  
recommended) are not supplied.  
Constructed of heavy gauge steel, the HS1000 will ac-  
cept most 2/3-inch format cameras with fixed focal  
length lenses ranging in size from 4 mm to 75 mm.  
There is no exposed mounting hardware securing the  
HS1000 to its mounting surface. Opening the enclo-  
sure can only be accomplished with a specially designed  
tool, eliminating the possibility of the enclosure being  
opened by unauthorized personnel. In addition, a fac-  
tory-installed tamper switch is mounted on the secured  
access cover.  
Designed to fit flush to the ceiling in a corner, an op-  
tional hood (HS1000H) allows the HS1000 to be  
mounted lower on the wall and still retain the integ-  
rity of the enclosure. Provisions are made for mount-  
ing 4-inch (10.16 cm) speakers on either side of the  
enclosure. The hinged front is supplied with an im-  
pact-resistant Lexan window with adequate area for  
the installation of an infrared illuminator.  
2
Pelco Manual C490M-D (1/96)  
 
4.1 CEILING MOUNTING (FLUSH)  
6. Make all appropriate connections (i.e., camera  
power, video (coax), lens, speakers, infrared illu-  
minators, heater/power kits).  
To mount the enclosure to a wall/ceiling, perform the  
following steps:  
7. Position the camera and tighten the 1/4-20 fasten-  
ers to secure the tilt table in place.  
1. Open the front cover by removing the four (4) 1/4-  
20 “Tampruf” screws.Aspecial socket is provided  
(fits 1/4-inch square drive). The cover hinges down.  
8. Close the cover and check that all components clear.  
Secure the cover with the four (4) 1/4-20 “Tampruf”  
screws provided.  
2. Using the mounting bracket as a template, mark  
and drill holes in the mounting surfaces.  
3. Attach the enclosure with the required fasteners.  
4. Route required cables through the back and/or top  
of the enclosure.  
5. Mount the camera/lens to the tilt table.  
Figure 1. HS1000 Dimension Drawing  
Pelco Manual C490M-D (1/96)  
3
 
4.2 MID-WALL MOUNTING  
4.4 OPTIONAL HB6000, HB6000/220,  
AND HB6024 HEATER/BLOWER KITS  
To mount the enclosure mid-wall, use the optional hood,  
HS1000H, and perform the following steps:  
The HB6000, HB6000/220, and HB6024 heater/blower  
kits require 120 VAC, 230 VAC, or 24 VAC respectively.  
They provide 80 watts of heat which is thermostati-  
cally controlled to turn on at 40°F (4.44° C) and turn  
off at 60°F (15.56° C). They also provide internal air  
circulation which is thermostatically controlled to turn  
on at 110°F (43.33° C) and off at 80°F (26.67° C).  
1. Follow steps 1-7 in Section 4.1.  
2. Attach the hood to the enclosure with the required  
fasteners provided (minimum 3/8" diameter rec-  
ommended).  
3. Close the cover and check that all components clear.  
Secure the cover with the four (4) 1/4-20 “Tampruf”  
screws provided.  
4.4.1 Recommended Cable Size  
CAUTION: When using a single power  
source for both the camera and accessories,  
the camera power consumption must be taken  
into consideration when determining the wire  
gauge.  
4.3 SPEAKER INSTALLATION  
The HS1000 provides two (2) positions for mounting  
small speakers (3" x 3" bolt pattern) to be provided by  
the user.  
The cable sizes listed in the table below, should be con-  
sidered as the minimum recommended sizes for use with  
the combination of blower/heater/camera.  
The speaker grills are shipped with a cover plate  
mounted over each on the inside. This plate must be  
removed prior to speaker installation.  
NOTE: The speakers mount to the front cover  
of the enclosure. Be sure to leave an adequate  
loop of cable to allow the cover to be opened.  
Recommended Cable Sizes  
Model  
Input Voltage  
Consumption  
Cable Size  
Cable Distance  
HB6000  
120 VAC  
90 watts  
22 Awg  
20 Awg  
18 Awg  
16 Awg  
464.7 ft (141.6 m)  
738.9 ft (225.2 m)  
1,175.5 ft (358.7 m)  
1,865.7 ft (568.7 m)  
HB6000/220  
HB6024  
230 VAC  
24 VAC  
90 watts  
90 watts  
24 Awg  
22 Awg  
20 Awg  
18 Awg  
16 Awg  
1,047.4 ft (319.2 m)  
1,666.0 ft (507.8 m)  
2,649.2 ft (807.5 m)  
4,214.6 ft (1,284.6 m)  
6,688.8 ft (2,038.7 m)  
20 Awg  
18 Awg  
16 Awg  
14 Awg  
31.5 ft (9.6 m)  
50.2 ft (15.3 m)  
79.6 ft (24.3 m)  
127.0 ft (38.7 m)  
4
Pelco Manual C490M-D (1/96)  
 
4.4.2 Heater/Blower Kit Installation  
4.4.2.2 Blower/PCB Assembly  
To install the HB6000/HB6000/220/HB6024, perform the  
following steps (refer to Figure 2).  
1. Open the cover.  
2. On the HS1000, the blower/PCB bracket is designed  
to attach to any two (2) adjacent studs used in retain-  
ing the bottom plate.  
4.4.2.1 Heater Assembly  
1. Open the cover.  
3. Remove any two adjacent nuts and washers retain-  
ing the bottom plate to the mounting frame.  
2. The heater bracket is designed to attach to any two  
(2) adjacent studs used in retaining the window.  
4. Place the blower/PCB bracket over the studs, then  
replace and tighten the hardware.  
3. Remove any two (2) adjacent nuts and washers on  
both sides of the window.  
4.4.2.3 Heater/Blower Wiring  
4. Place the heater brackets on the studs, with the heat-  
ers angled away from the window, then replace and  
tighten the hardware.  
The blower is factory wired to the PCB assembly. Con-  
nect the heaters to the PCB assembly as shown in the  
respective wiring diagrams (Figure 4, Figure 5, or Figure  
6). Supply AC line voltage (230 VAC, 120 VAC, or 24  
VAC) as shown.  
Figure 2. HB6000, HB6000/220, and HB6024 Assembly  
Pelco Manual C490M-D (1/96)  
5
 
4.5 ELECTRICAL CONNECTION  
4.6.1 Tamper Switch Wiring  
After the cable has been routed, all wire connections  
should be made (i.e., video, lens, camera power, heaters).  
A 6-position terminal block has been provided to assist  
in this.  
The tamper switch comes with both a “Normally Open”  
contact and a “Normally Closed” contact.  
For a “Normally Open” circuit, use the “open ” and “com-  
mon” terminals; for a “Normally Closed” circuit, use the  
“closed” and “common” terminals.  
CAUTION: When a single power source is  
used for both the camera and accessories, the  
camera power consumption must be taken into  
consideration when determining the wire gauge.  
Also, make certain that all electrical connections  
are done properly and meet electrical codes.  
5.0 CARE AND MAINTENANCE  
Maintenance performed at regular intervals will help pro-  
long the operational life and appearance of the equipment.  
Clean the Lexan window with a mild nonabrasive deter-  
gent in water with a soft cloth regularly to maintain pic-  
ture clarity. For a heavily soiled window, use vinyl cleaner.  
4.6  
TAMPER SWITCH INSTALLATION  
The HS1000 enclosures come standard from the fac-  
tory with a tamper switch installed. Should it become  
necessary to install a replacement switch, refer to Fig-  
ure 3 for the correct position of the bracket/switch and  
perform the following steps:  
NOTE: Pelco offers a 24-hour, seven-day-a  
week Technical Assistance Program (TAP)  
designed to assist any customer with a technical  
problem involving Pelco equipment whether it’s  
the weekend or late at night. For technical  
assistance dial (800) 289-9100 and you will be  
connected to a PelcoTAPmember who is trained  
to answer your questions.  
1. Remove the front cover.  
2. Install the bracket/switch and secure with  
lockwashers and nuts.  
Pelco also guarantees one-day turnaround on any Pelco  
equipment sent in for repair. This includes warranty and  
non-warranty items. Refer to the section on warranty and  
return information in this manual for the proper proce-  
dure.  
Figure 3. HS1000 SeriesTamper Switch Installation  
6
Pelco Manual C490M-D (1/96)  
 
Figure 4. HB6000/220 Heater/Blower Kit Wiring Diagram (230 VAC)  
Figure 5. HB6000 Heater/Blower Kit Wiring Diagram (120 VAC)  
Pelco Manual C490M-D (1/96)  
7
 
Figure 6. HB6024 Heater/Blower Kit Wiring Diagram (24 VAC)  
6.0 MECHANICAL PARTS LIST FOR HS1000 ENCLOSURE (FIGURE 7)  
Item No.  
Qty  
Description  
Part Number  
1
2
1
2
Plate, Cover, Front  
HS10004013COMP  
HS80004115COMP  
HS100010009  
Plate, Grill, Block-Off  
3
1
Window, HS1000, Clear, 12" x 15" x .50"  
Switch, Tamper  
Bracket, Switch, Break-In  
Bracket, Mounting  
Hood, Mid Wall Mount (optional accessory)  
Tilt Table  
Bracket, Tilt Table Mount  
4
1
SWI1DM401  
5
1
HS10004313COMP  
HS10004011COMP  
HS1000H  
AH80004013COMP  
AH80004014COMP  
HS10004005COMP  
HS10004008COMP  
ZH1/4-20NUTCH  
ZH1/4WSSL  
ZH260X562X65C  
ZH1/420NUTCHN  
ZH255X1.50X62  
ZH1/420X.625CH  
ZH10-32NUTSH  
ZH10LWSSL  
6
1
7
1
8
1
9
1
10  
11  
A
B
C
D
E
F
G
H
I
1
Plate, Bottom, Corner Mount  
Hinge, Cover  
1
11  
13  
17  
6
1/4-20 Hex, Finished Nut SS  
Washer, Split Lock, 1/4-inch SS  
Washer, Flat, 3/16-inch SS  
Nut Lock 1/4-20 Nylon Insert Lock Nut  
Washer, Fender, 1/4-inch Black Oxide  
Bolt, 1/4-20 x 5/8-inch, Hex C/S SS  
Nut, Hex, 10-32 SS  
Washer, Split Lock, #10 SS  
Washer, Flat, #10 SS  
Screw, 1/4-20 x 1/2", Round, Tampruf, #10 SS  
6
2
4
4
4
ZH204X436X60C  
ZH1/4-20X.50SRT  
J
4
8
Pelco Manual C490M-D (1/96)  
 
7.0 EXPLODED ASSEMBLY DIAGRAM  
Figure 7. HS1000 Enclosure Exploded Assembly Diagram  
Pelco Manual C490M-D (1/96)  
9
 
8.0 SPECIFICATIONS  
MECHANICAL  
9.0 MODELS  
The HS1000 high-security corner mount enclosure has  
been designed for installations such as parking garages,  
prisons, detention cells and many other areas requiring  
maximum protection from vandalism. Below is a list  
of available HS1000 enclosure options.  
Window:  
1/2" (12.7 mm) thick impact and  
abrasion resistant clear Lexan  
Camera  
Mounting:  
Adjustable tilt table  
9.1 OPTIONS  
Maximum  
Camera/Lens  
Size:  
HS1000H  
Hood for mid-wall mounting of  
HS1000 enclosure.  
Accepts camera/lens combinations  
(including BNC connector) up to:  
12.0" L x 6.0" W x 6.0" H  
HB6000  
120 VAC thermostatically controlled  
heater and blower.  
(30.48 cm x 15.24 cm x 15.24 cm)  
Provides 80 watts of heat: activates  
ON at 40°F (4.44° C); and OFF at  
60°F (15.56° C).  
Enclosure  
Mounting:  
Twelve (12) .390" (0.99 cm) diam-  
eter holes on protected rear surfaces  
(top and back)  
Provides internal air circulation: ac-  
tivates ON at 110°F (43.33° C); and  
OFF at 80°F (26.67° C).  
Security:  
Tamper-resistant screws  
N.O./N.C. switch contact on cover  
HB6000/220  
HB6024  
Same as HB6000 except operates at  
230 VAC.  
Tamper Switch: Plunger type door switch with “pull  
to cheat” feature. N.O./N.C. contacts  
clearly marked on body of switch.  
DM electrical rating: 10A, 125V.  
Plunger type with .20" (0.51 cm)  
Same as HB6000 except operates at  
24 VAC.  
ELECTRICAL  
Cable Entry:  
Six-position terminal block. Cable  
entry access through back and top  
Tamper Switch: 1/4" (.63 cm) quick connect. N.O./  
N.C. clearly marked on switch body.  
10A, maximum switching current  
125V, maximum switching voltage.  
GENERAL  
Construction:  
Formed 10 gauge .134" (0.34 cm)  
steel  
Finish:  
Poly vinyl powder coat  
See Figure 1  
Dimensions:  
Environment:  
Unit Weight:  
Indoor, 32° to 120° F (0° to 48.89° C)  
40 lbs 13 oz (18.36 kg)  
10  
Pelco Manual C490M-D (1/96)  
 
Notes:  
Pelco Manual C490M-D (1/96)  
11  
 
10.0 WARRANTY AND RETURN  
INFORMATION  
WARRANTY  
RETURNS  
Pelco will repair or replace, without charge, any merchandise proved  
defectiveinmaterialorworkmanshipforaperiodofoneyearafterthedate  
of shipment.  
In order to expedite parts returned to the factory for repair or credit, please  
call the factory at (800) 289-9100 or (559) 292-1981 to obtain an  
authorization number (CA number if returned for credit, and RA number  
if returned for repair).  
Exceptions to this warranty are as noted below:  
All merchandise returned for credit may be subject to a 20% restocking  
and refurbishing charge.  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and  
keyboard).  
Three years on Camclosure® and fixed camera models, except the  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,  
and MC3651H-2X camera models, which have a five-year warranty.  
Goods returned for repair or credit should be clearly identified with the  
assigned CA or RA number and freight should be prepaid. Ship to the  
appropriate address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto  
Rico, send goods to:  
Service Department  
Pelco  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and  
DF5/DF8 Series fixed dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, includ-  
ing when used in continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding  
wiper blades).  
3500 Pelco Way  
Clovis, CA 93612-5699  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto  
Rico and are instructed to return goods to the USA, you may do one of the  
following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Eighteen months on DX Series digital video recorders, NVR300  
Series network video recorders, and EnduraSeries distributed  
network-based video products.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
One year (except video heads) on video cassette recorders (VCRs).  
Video heads will be covered for a period of six months.  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods  
to:  
Six months on all pan and tilts, scanners or preset lenses used in  
continuousmotionapplications(thatis,presetscan,tourandautoscan  
modes).  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
Pelco will warrant all replacement parts and repairs for 90 days from the  
date of Pelco shipment. All goods requiring warranty repair shall be sent  
freight prepaid to Pelco, Clovis, California. Repairs made necessary by  
reason of misuse, alteration, normal wear, or accident are not covered  
under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or  
loss resulting from the specific use or application made of the Products.  
Pelco’s liability for any claim, whether based on breach of contract,  
negligence, infringement of any rights of any party or product liability,  
relating to the Products shall not exceed the price paid by the Dealer to  
Pelco for such Products. In no event will Pelco be liable for any special,  
incidental or consequential damages (including loss of use, loss of profit  
and claims of third parties) however caused, whether by the negligence  
of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The  
Dealer may also have additional rights, which are subject to variation from  
state to state.  
Ifawarrantyrepairisrequired,theDealermustcontactPelcoat(800) 289-  
9100 or (559) 292-1981 to obtain a Repair Authorization number (RA),  
and provide the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice  
number  
3. Details of the defect or problem If there is a dispute regarding the  
warranty of a product which does not fall under the warranty conditions  
stated above, please include a written explanation with the product  
when returned.  
Method of return shipment shall be the same or equal to the method by  
which the item was received by Pelco.  
12  
Pelco Manual C490M-D (1/96)  
 

Philips Baby Accessories SCF680 27 User Manual
Philips Battery Charger LR6EB8A User Manual
Philips Clock Radio AJ260 05 User Manual
Philips Digital Camera SPZ6500 00 User Manual
Philips Headphones SHC8565 00 User Manual
Philips Portable Radio PMST6428 User Manual
Philips TV Mount SQM5312 User Manual
Pioneer Blu ray Player BDP 43FD User Manual
Pioneer Car Stereo System SX 3400 User Manual